Glazed aluminium doors offers high security

SAELZER security aluminium doors are available in 2 different series: the series S2es and S6es. They differ according the resistance against ballistic attacks. The series S6es offer protection against ballistic attacks up to the resistance level FB4-NS according the European standard for bullet resistance. The series S2es ensures security up to the highest resistance class FB7-NS.
Both series offer the same protection levels in forced entry and blast resistance.
Despite the high security SAELZER doors warrant, the architectural design is very attractive. The SAELZER aluminium profile system permits various constructions for individual requirements - whether modern or historical style. The doors can be designed elegant e.g. for the use in an embassy or private house as well as for tough applications such as barracks.
The SAELZER aluminum doors have optimum thermal insulation values (see table below, tested according to DIN EN ISO 10077-2).

Brochure: Aluminium door S2es & S6es pdf icon

Security* Standard Class series S2es Class series S6es
Forced entry resistance

According to DIN EN 1627-1630
Glazing according to DIN EN 356
Tested inside and outside opening doors

Up to RC4
Up to P8B
Up to RC4
Up to P8B
Bullet resistance According to DIN EN 1522-1523
Glazing according to DIN EN 1063
According to UL 752
Tested inside and outside opening doors
Up to FB7-NS
Up to BR7-NS

Level 8
Up to FB4-NS
Up to BR4-NS
 
-
Blast resistance According to DIN EN 13123 and according to customer requirements e.g. tested
with 100 kg + 500 kg explosive. Glazing according to SAELZER specification.
Up to EXR2
84 kPa - 790 kPa
(0.84 bar - 7.9 bar) reflected pressure.
GSA level 2
Up to EXR2
84 kPa - 790 kPa
(0.84 bar - 7.9 bar) reflected pressure.
GSA level 2
Performance characteristics according to DIN EN 14351 
Resistance against wind load Depending on the type up to class C5
Water tightness Depending on the type classes 1A up to E750
Air permeability Depending on the type up to class 4
Impact resistance Depending on the type up to class 5
Thermal insulation UD = 1.5 up to 1.8 W/m2K; values vary depending on the element size and glazing
Sound insulation Up to RW 38dB; values vary depending on the element size and glazing
Life cycle Suitable for heavily frequented entrances and exits. Series S2es:
Details on request due to vary security components and weights.
Series S6es:
Class 6: 200,000 cycles with 400 kg weight of the wing.
Class 7: 500,000 cycles with 350 kg weight of the wing.
Sizes | glazing | hinges | locking
Profile depth   135 mm 110 mm
Glazing Security class of the glazing is the same resistance level as the complex construction. Glass thicknesses up to 97 mm, glazing bead flush. Higher thicknesses possible. Glass thicknesses up to 75 mm, glazing bead flush. Higher thicknesses possible.
Glazing bead There is no visible screwing of the glazing bead required due to the stable design. Also no glueing necessary (natural glazing rebate ventilation and water circuit). Glazing beads are anchored pressure and impact resistant in the slot of the profiles.
Height Approved max. height of the wing: 3.00 m
Recommended max. height of the wing: 2.50 m
. Height e.g. depending on the wing weight and construction site (bimetal effect).
Profile widths Despite high security components small profile widths.
Surface Anodized or powder coated, also clad with different materials such as stainless steel, stone, bronze, various types of wood.
Locks
fittings
All locks which are approved in the tested security class of the door. Mechanical, electro-mechanical or motorized locks, single or multiple locking. Doors for emergency exits tested according to DIN 179 and DIN 1125 (panic bar) up to RC4. Applicable as interlocking door with special control system possible. All tested and certified fittings can be installed in the respective security level. 
Hinges | wing weights Hinges for heavy weights. Easy operating despite heavy wing weights. Hinges bear wing weights up to 400 kg, up to 600 kg with floor pivot.
Threshold, floor gasket Threshold or adjustable floor gasket. Barrier free entrances and exits are possible.
Installation Installation in several building materials. Bullet resistance: a bullet resistant wall connection is tested and recommended. 
* Higher requirements upon request.