Protecting lives

SAELZER offers different kinds of fire and smoke resistant doors:

  1. Steel doors Series S4: combined protection against fire (EI30/BS120), forced entry (up to RC5),  bullets (up FB7-NS) and explosion (up EXR5)
  2. Series SECUFIRE® combined protection against fire / smoke (EI30, EW60, E60, C5S200), forced entry (up to RC4), bullets (up FB4-NS) and explosion (pressure up to 1.53 bar)
  3. Tubular frame door in aluminium, steel and stainless steel. For applications where the fire and smoke resistance has priority, SAELZER offers approved fire and smoke resistant doors in different security levels and materials and with forced entry resistant up to RC3 (see chart below).

Equipment components (examples):

  • Access control.
  • Doors can be equipped with anti-panic function according to DIN EN 179 and DIN EN 1125 and can be used as emergency or panic door.
  • With escape door control.
  • Automatic door.

The doors are available with single- or double sashes in different design variations.

Tubular frame door in aluminium, steel, stainless steel
Security Standard Aluminium
different systems
Steel or
stainless steel

different systems
Aluminium
smoke protection
Steel / stainless steel
smoke protection
Fire
resistance*
Classified according to
DIN EN 13501-2
EI30 (T30)
EW30
 EI90 (T90) EI 30 (T30) EI90 (T90)  --- ---
Smoke
resistance*
Classified according to
DIN EN 13501-2
C5S200
(RS1+2)
C5S200
(RS1+2)
C5S200
(RS1+2)
C5S200
(RS1+2)
C5S200
(RS1+2)
C5S200
(RS1+2)
Forced entry
resist
ance
According to DIN EN
1627-1630 (for higher resistance please see
SECUFIRE® or steel door Series S4).
Up to RC3 --- Up to RC3 --- Up to RC2 Up to RC3
Bullet resistance According DIN 1522 + 1523 --- --- --- --- --- Up to FB4-NS
Bullet, blast resistance If additional to the fire and smoke resistance, bullet and blast resistance is required please see page SECUFIRE® or steel door Series S4.
* On the basis of the positive test report and the opinion of experts an approval in individual cases is possible.