Protection of your life

Multi-functional doors in steel tube frame construction for elegant, slim elements with expansive glazing. Combined safety and security including for ex. fire and smoke protection plus forced entry and bullet resistance in elegantly neutral design.

To fulfill the plenty of different security requirements the series SECUFIRE® is available in four version for the construction of doors, windows and partition walls:

SECUFIRE® S (Profile depth 70 mm / Glazing, panel thickness max. 57 mm)
SECUFIRE® U (Profile depth 83 mm / Glazing, panel thickness max. 70 mm)
SECUFIRE® F (Profile depth 75 mm / Glazing, panel thickness max. 62 mm)
SECUFIRE® P (Profile depth 65 mm / Glazing, panel thickness max. 52 mm)

Safety classes:
einbruchdurchschusssprengwirkungshemmungfeuerrauchdichtheitausbruch

  • Fire resistant door with top light integrated in a partition wall.

    Fire resistant door with top light integrated in a partition wall.

  • Fire and smoke resistant door with side lights.

    Fire and smoke resistant door with side lights.

  • Fire resistant door. Application: bank.

    Fire resistant door. Application: bank.

  • Fire and breakout resistant door series SECUFIRE.

    Fire and breakout resistant door series SECUFIRE.

    Application: prison.

  • Combined protection against fire, forced entry and ballistic attacks.

    Combined protection against fire, forced entry and ballistic attacks.

» Technical data

Security steel frame door series SECUFIRE ®
Types | Installation depth | glazing
designvarianten
Types

F01 FF 1F geschnittenF02 FE 1F DK geschnittenF03 FE 1F D geschnittenF04 FE 1F K geschnittenF05 FE 2F DK DK geschnittenF06 FE 2F DK D geschnittenF07 FE 5F FF K OL FF DK OL D geschnittenF08 FE auswarts 1F klapp geschnittenF09 FE auswarts 1F D geschnittenT10 T HR 2flgF11 FF Schalter 1F geschnitten

The doors are combinable with all products within the SYSTEM SAELZER.

profilbautiefe verglasung
Profile depth | glazing
Profile depth and glazing/panel thickness depends on the selected model.
Infill option: glazing, panel, grilles and louver.
hoehe und breite
Sizes
Large doors are tested e.g. single door, forced entry resistant in level RC4, frame measurement 1.700 x
3.000 mm. Recommended door size up to 1.250 x 2.500 mm (size depends on the door leaf weight and on the place of installation, bi-metal effect).
oberflaeche
Surface
Primed, painted or powder coated, over clad with timber, stainless steel, stone, bronze and other options.
Security according international standards & individual requirements
einbruch
Forced entry resistance*
According to DIN EN 1627-1630 resp. glazing according to DIN 356
up to RC4 resp. glazing up to P8B
durchschuss
Bullet resistance*

According to DIN EN 1522-1523 resp. glazing according to DIN EN 1063
up to FB4-NS resp. glazing up to BR4-NS.

sprengwirkungshemmung
Blast resistance*
According to international standards and customised requirements test with different explosive charges up to 500 kg, GSA2.
feuer
Fire resistant**
Classified according DIN EN 4102 up to T90** resp. according to DIN EN 13501-2 up to EI90**.
rauchdichtheit
Smoke**
Classified according DIN EN 18095 in RS-1/RS-2** resp. according to DIN EN 13501-2 up to S200**.
Performance according to DIN EN 14351
windlast
Resistance against windload
Depending on the type up to level C3 (test pressure: 1.200 Pa)

schlagregen
Water tightness

Depending on the type up to level E 900 (test pressure: 900 Pa)
luftdurchlaessigkeit
Air permeability
Depending on the type up to level 4 (test pressure: 600 Pa)
stossfestigkeit
Impact resistance
Depending on the type up to level 1 (drop height: 200 mm)
waermedurchgangskoeffizient
Thermal insulation
Depending on the type up to UW 0,9 W/m²K
schall
Sound insulation
Depending on the type up to RW 46 dB
dauerfunktion
Life cycle test
Level C5: 200.000 open and closing cycles with 400 kg weight of the leaf.
Further technical properties
Locks | fittings General: All locks which are approved in the tested security class of the door. Mechanical, electro-mechanical or motorized locks, single or multiple locking. Doors for emergency exits tested according to DIN 179 and DIN 1125 (panic bar) up to RC4. Applicable as interlocking door with special control system possible. All tested and certified fittings can be in-stalled in the respective security level.
For the use in prison and forensic hospitals: with special prison locks, simple locking systems up to resistant level RC3 and with multiple locking systems up to level RC4.

Hardware | weight

Hinges for heavy weights. Options: welded hinges, screwed hinges or concealed mounted hinges . Easy operating despite heavy wing weights. Hinges bear wing weights up to 400 kg.
Threshold | floor gasket Threshold or adjustable floor gasket. Barrier free entrances and exits are possible.
Profile width Despite high security properties small profile width: minimum 30mm.
Glazing bead Due to the stable design, no visible screwing of the glazing bead is required and no glueing of the glazing is necessary, this offer a natural glazing rebate ventilation and water circuit.
Installation Installation in several building material is permitted. Bullet resistance: a bullet resistant wall connection is tested and recommended.

* higher requirements upon request. **individual approval on the base of the positive test reports