Certified Security
The high-security aluminium door in the S2es-d series provides combined protection against break-ins, bullets and explosions up to the highest classes. The system has withstood break-in attempts at accredited test institutes using powerful electrical tools (such as jigsaws and large angle grinders) up to the highest class RC6. The high-security door also offers certified protection against shots with long firearms and armour-piercing ammunition up to the highest class FB7-NS* as well as against bomb attacks (500 kg of explosives | distance of 28 m). There are also certifications in class EXR2.
The S2es-d series features high functionality, elegance, low-maintenance durability and numerous individual design configurations.
Even the fully glazed version of the door system can withstand heavy attacks with electrical tools such as angle grinders and drills in resistance class RC5.
* see also S6es-d series
Security according international standards & individual requirements
Aluminium door S2es-series
Frame and special glazing tested as a complete unit in various designs in accordance with DIN EN 1627-1630 up to RC5. A note about the glazing: In the high resistance classes RC5 and RC6, the P7B and P8B glazing tested in line with DIN EN 356 must be replaced with glazing of higher quality, as it is only tested with blows with an axe. This glazing cannot withstand attacks with the electrical tools used in these high burglar resistance classes.
In accordance with DIN EN 1522-1523 up to FB7-NS, glazing in accordance with DIN EN 1063 up to BR7-NS.
In accordance with DIN EN 13123-2 and DIN EN 13124-2 up to EXR2. Tested in accordance with customer-specific requirements, e.g. with 500 kg of explosives in 28 m. Glazing as per SÄLZER design. GSA 2 ("Very High" protection level), ISO B ("No Hazard" hazard rating).
Higher security requirements can also be met at the customer's request. We would be happy to help put together your security concept in a personal consultation.
Design | Basic depths | Glazing | Surface
Types







The doors are combinable with all products, prepared for installation in the SÄLZER mullion-transom facade.
Profile depth | glazing
Frame: 135 mm | glass thickness up to 97 mm.
Sizes
Large doors are tested e.g. single door forced entry resistant in level RC4, frame measurement 1.700 x
3.000 mm. Recommended door size up to 1.250 x 2.500 mm (size depends on the door leaf weight and on the place of installation, bi-metal effect).
Surface
Anodised or powder coated, over clad with timber, stainless steel, stone, bronze and other options.
Resistance against wind load
Depending on the type up to level C5 (test pressure: 2.000 Pa)
Water tightness
Depending on the type up to level E 750 (test pressure: 750 Pa)
Air permeability
Depending on the type up to level 4 (test pressure: 600 Pa)
Impact resistance
Depending on the type up to level 5 (drop height: 950 mm)
Thermal insulation
Depending on the type of door
UD = 1,7 - 1,9 W/m²K (double glazing)
UD = 1,5 - 1,8 W/m²K (tripple glazing).
Sound insulation
Depending on the type up to RW 47 dB
Life cycle test
Suitable for frequently used entrances and exits.
Level 6: 200.000 cycles with 400 kg leaf weight. Level 7: 500.000 cycles with 350 kg leaf weight. For higher door leaf weights up to 800 kg floor pivot bearings are
used.
Further technical properties
Locks | fittings | All locks which are approved in the tested security class of the door. Mechanical, electro-mechanical or motorized locks, single or multiple locking. Doors for emergency exits tested according to DIN 179 and DIN 1125 (panic bar) up to RC 5. Applicable as interlocking door with special control system possible. All tested and certified fittings can be in-stalled in the respective security level. |
Hardware | weight | Suitable for frequently used entrances and exits. Level 6: 200.000 cycles with 400 kg leaf weight. Level 7: 500.000 cycles with 350 kg leaf weight. For higher door leaf weights up to 800 kg floor pivot bearings are used. |
Threshold | floor gasket | Threshold or adjustable floor gasket. Barrier free entrances and exits are possible. |
Profile width | Despite high security properties small profile width. |
Glazing bead | Due to the stable design, no visible screwing of the glazing bead is required and no glueing of the glazing is necessary, this offer a natural glazing rebate ventilation and water circuit. |
Installation | Installation in several building materials and in the facade series S1 is permitted. Bullet resistance: a bullet resistant wall connection is tested and recommended. |
Areas of application

Tested with a wide range of locking systems: mechanical, electromechanical or motorized locks, single or multiple locking, selflocking systems. The doors can also be automated using drive systems.

Also tested and certified as double door up to RC5, FB7-NS and blast resistant.

Personal consultation
Every building project is unique and the perfect high-security solution depends on a number of different factors. Contact us now and we will work out your requirements together, so that you can have the perfect security system and protect what is yours and what is important.