Multiple tests against various threats
Security window in steel tubular frame construction for elegant, slimline structures with a high proportion of glass. The stable yet slimline steel tubular frame construction in the SECUFIRE® series provides elegant protection against multiple threats. Even with the combined protection against a range of different types of threat, high resistance classes can be achieved with a high proportion of glass:
Forced entry and break-out resistance up to RC4 (test on both sides), bullet resistance up to FB4-NS and protection against bomb attacks (100 kg of explosives | distance of 22 m). In addition, fire protection up to F90/EI90 can be provided depending on the design, place of use and the other security requirements.
Four different types
To comply with all customer requirements concerning security and design the SECUFIRE® series is available in four different types:
- SECUFIRE® S (profile depth 70 mm/max. glass thickness 57 mm)
- SECUFIRE® U (profile depth 83 mm/ max. glass thickness 70 mm)
- SECUFIRE® F (profile depth 75 mm/ max. glass thickness 62 mm)
- SECUFIRE® P (profile depth 65 mm / max. glass thickness 52 mm)
Security according international standards & individual requirements
Steel window series SECUFIRE®
In accordance with DIN EN 1627-1630 up to RC4, glazing in accordance with DIN EN 356 up to P8B.
In accordence with DIN EN 1522-1523, up to FB4-NS, glazing in accordence with DIN EN 1063 up to BR4-NS.
According to customised requirements, tested in various open range tests with different explosive charges, reflected pressure up to 272,2 kPa (2,722 bar), glazing composition according SALZER requirements, GSA2.
Classified according to DIN 4102 up to F90** resp. DIN EN 13501-2 up to EI 90
Classified according to DIN 18095 in RS-12 resp. DIN EN 13501-2 up to S200.
Higher security requirements can also be met at the customer's request. We would be happy to help put together your security concept in a personal consultation.
Types | installation depth | glazing
Types


Profile depth | glazing
Profile depth and glass thickness depends on the selected model range S, U, F or P.
Surface
Primed, painted or powder coated, customised colour design, over clad with timber, stainless steel, stone, bronze and other options.
Resistance against wind load
Depending on the type up to level C3 (test pressure: 1.200 Pa)
Water tightness
Depending on the type up to level E 900 (test pressure: 900 Pa)
Air permeability
Depending on the type up to level 4 (test pressure: 600 Pa)
Impact resistance
Depending on the type up to level 1 (drop height: 200 mm)
Thermal insulation
Depending on the type up to UW 0,9 W/m²K
Sound insulation
Depending on the type up to RW 47 dB
Further technical properties
Profile widths | Despite the high security components smal profile widths of only 30 mm. |
Installation | Installation in several building materials permitted. Bullet resistance: a bullet resistant wall connection is tested and recommended. |

Personal consultation
Every building project is unique and the perfect high-security solution depends on a number of different factors. Contact us now and we will work out your requirements together, so that you can have the perfect security system and protect what is yours and what is important.